Hello everybody:
I am adjusting the LO hardware of my 2754P and there are some things that I
can not find or undestand:
After pressing shift 0 , loops calibration, overall system option the first
message is:
Connect a DVM on TP1058...etc (no problem )
(the meter shows 17mV)
Adjust frequency control
for a reading of 0.000 +/- 2mV
(problem WHICH FREQUENCY CONTROL?? OR POTENTIOMETER OR RESISTOR???)
The freuquency control board???
2.Connect a DVM on oint B of the controlled oscillator board and ground..
WHERE THE HECK IS POINT B AND WHERE IS THE CONTROLLED OSCILLATOR BOARD???
Thank you your help |
|
| Back to top |
|
 |
|
|
Henry Kolesnik Guest
|
Posted: Mon Jan 10, 2005 10:33 pm Post subject: Re: Tek 2754P LO adjustment |
|
|
there's a Tek group on Yahoo & SA are discussed.
http://groups.yahoo.com/group/TekScopes/
--
73
Hank WD5JFR
"rfgelitronics" <no_spam@nowhere.com> wrote in message
news:aYyEd.9057$wZ2.6923@newssvr13.news.prodigy.com...
| Quote: | Hello everybody:
I am adjusting the LO hardware of my 2754P and there are some things that
I can not find or undestand:
After pressing shift 0 , loops calibration, overall system option the
first message is:
Connect a DVM on TP1058...etc (no problem )
(the meter shows 17mV)
Adjust frequency control
for a reading of 0.000 +/- 2mV
(problem WHICH FREQUENCY CONTROL?? OR POTENTIOMETER OR RESISTOR???)
The freuquency control board???
2.Connect a DVM on oint B of the controlled oscillator board and ground..
WHERE THE HECK IS POINT B AND WHERE IS THE CONTROLLED OSCILLATOR BOARD???
Thank you your help
|
|
|
| Back to top |
|
 |
rfgelitronics Guest
|
Posted: Mon Jan 10, 2005 10:40 pm Post subject: Re: Tek 2754P LO adjustment |
|
|
This is an spectrum analyzer, but I will give it a try..
Thank you
"Henry Kolesnik" <kolesnik@sbcglobal.net> wrote in message
news:x%yEd.14040$iC4.5559@newssvr30.news.prodigy.com...
| Quote: | there's a Tek group on Yahoo & SA are discussed.
http://groups.yahoo.com/group/TekScopes/
--
73
Hank WD5JFR
"rfgelitronics" <no_spam@nowhere.com> wrote in message
news:aYyEd.9057$wZ2.6923@newssvr13.news.prodigy.com...
Hello everybody:
I am adjusting the LO hardware of my 2754P and there are some things that
I can not find or undestand:
After pressing shift 0 , loops calibration, overall system option the
first message is:
Connect a DVM on TP1058...etc (no problem )
(the meter shows 17mV)
Adjust frequency control
for a reading of 0.000 +/- 2mV
(problem WHICH FREQUENCY CONTROL?? OR POTENTIOMETER OR RESISTOR???)
The freuquency control board???
2.Connect a DVM on oint B of the controlled oscillator board and ground..
WHERE THE HECK IS POINT B AND WHERE IS THE CONTROLLED OSCILLATOR BOARD???
Thank you your help
|
|
|
| Back to top |
|
 |
|